China Manufacturers supply flange low cost ultrasonic Flow Meter/water flow meter/liquid flow meter/milk flow meter

The GXUM2000 series ultrasonic flow meter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation. If you contact the temperature sensor, it can also measure he quantity of heat.

Product description

1. GXUMF2000 series integrated type ultrasonic flow meter


Items

Specifications

Main unit

Accuracy

Better than ±1%

Repeatability

Better than 0.2%

Principle

Transit-time measuring principle

Measurement

Period

500ms

Display

LCD with backlight,display accumulated flow/heat, instantaneous flow/heat, velocity, time etc.

Output

Analogue output: 4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%.

OCT output: Frequency signal (1~9999HZ)

Relay output: over 20 source signal (no signal, reverse flow etc.)

RS485 serial port

Input

Three analogue input

Three-wire PT100 resistor input (optional)

Other functions

Automatically record the totaliser data of the last 64 days / 64 months / 5 years;

The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

The instrument working status of the last 64 days

pipe

material

Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed

Size

15-6000mm

Straight pipe section

In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter)

Liquid

Types

Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid

Temperature

Standard: -30°c - 90°c ,High-temperature:-30°c- 160°c

Turbidity

Less than 10000ppm, with a little bubble

Flow Direction

Bi-directional measuring, net flow/heat measuring

Environment

Temperature

Main Unit: -30°c - 80°c

Transducer: -40℃ -110℃, Temperature transducer: select on enquiry

Humidity

Main Unit: 85% RH

Transducer: water-immersible, water depth less than 3m

Cable

Twisted Pair Line, standard length of 20m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement.

RS-485 interface, transmission distance up to 1000m

Power Supply

AC220V or DC24V

Power Consumption

Less than 1.5W

Protocols

MODBUS, M-BUS, Fuji extended protocol and other factory protocol

2. GXUMS2000 series split type ultrasonic flowmeter


Items

Specifications

Main unit

Accuracy

Better than ±1%

Repeatability

Better than 0.2%

Principle

Transit-time measuring principle

Measurement

Period

500ms

Display

LCD with backlight,display accumulated flow/heat, instantaneous flow/heat, velocity, time etc.

Output

Analogue output: 4-20mA or 0-20mA current output. Impedance 01kW. Accuracy 0.1%.

OCT output: Frequency signal (1~9999HZ)

Relay output: over 20 source signal (no signal, reverse flow etc.)

RS485 serial port

Input

Three analogue input

Three-wire PT100 resistor input (optional)

Other functions

Automatically record the totaliser data of the last 64 days / 64 months / 5 years;

The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

The instrument working status of the last 64 days

pipe

material

Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed

Size

15-6000mm

Straight pipe section

In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter)

Liquid

Types

Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid

Temperature

Standard: -30°c - 90°c ,High-temperature:-30°c - 160°c

Turbidity

Less than 10000ppm, with a little bubble

Flow Direction

Bi-directional measuring, net flow/heat measuring

Environment

Temperature

Main Unit: -30°c - 80°c

Transducer: -40 -110, Temperature transducer: select on enquiry

Humidity


China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

China Manufacturers supply flange low cost ultrasonic Flow Meter/water flow meter/liquid f Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Xi'an Kacise Optronics Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0