KTFM Series Turbine Flow Meter

Description

KTFM turbine flow meter is the use of advanced low-power single-chip microprocessor technology developed turbine flow sensor and display totalizer integration of new smart meter, with a compact structure, intuitive readings clear, high reliability, without outside power interference, anti-lightning, obvious low cost advantage, it is widely used to measure the closed pipe and stainless steel 1Cr18Ni9Ti, 2Cr13 and corundum Al2O3, carbide not corrode, and no fibers, particles and other impurities, kinematic viscosity at operating temperature is less than 5 × 10-6m² / s of liquid, for kinematic viscosity more than 5 × 10-6m² / s of liquid, can be quantitative control, excessive alarm, etc., is an ideal flow metering and energy meter.
Measurement objects: oil, organic liquids, inorganic liquid, liquefied petroleum gas, natural gas, coal gas and cryogenic fluids.

Features

☆ High accuracy, generally up to ±1%R, ±0.5%R, high accuracy up to 0.2%R
☆ Good repeatability, short-term repeatability up to 0.05%~0.2%, in the trade settlement is the preferred choice of flow meter.
☆ Output pulse frequency signal, no zero drift and strong anti-interference ability.
☆ High frequency signal(3~4KHz) can be obtained, the signal resolution is strong.
☆ Wide range, medium and large diameter up to 1:20, small caliber 1:10.
☆ Can be customized, for example Low temperature type, Bi-Directional type, Mixed sand type and Underground type etc.
☆ Can be made into an insert type, suitable for large diameter measurement, the pressure loss is small, the price is low, take it out with not cut off the liquid.

Applications

☆ Liquefied petroleum gas, refined oil and light crude oil transport and gathering stations, the first and terminal station of large crude oil pipeline for trade settlement.
☆ Widely used in petroleum, chemical, metallurgy, paper and other industries to measure the volume of liquid flow and total volume.

Specifications

Paremeter
Value
Unit
Diameter
Thread
4, 6, 10, 15, 20, 25, 32, 40, 50, 65, 80
mm
Flange(Clamp)
15, 20, 25, 32, 40, 50, 65, 80, 100, 125,150, 200
mm
Insertion
150, 200, 250, 300, 350, 400, 500~1100
mm
Accuracy
±1, ±0.5, ±0.2(customized)
%R
Range ratio
1:10, 1:15, 1:20
Sensor material
304, 316(L) stainless steel etc.
Working environment
Medium temp.
-20~120
°C
Ambient temp
-20~60
°C
Relative humidity
5%~90%
Atmospheric pressure
86~106
KPa
Signal output
Pulse,4~20mA
Comm interface
RS485,HART etc.
Power supply
External power
+24+15%,Ripple ≤±5%,
Applying to 4~20mA,Pulse,RS485
VDC
Internal power
1 group 3.0V10AH lithium battery,
working voltage 2.0~3.0V
Signal line interface
Basic type
Houseman connector or own three-core cable
Explosion proof type
Internal thread M20×1.5
Explosive-proof grade
ExiaIICT4 or ExdIIBT6
Protection level
IP65 or higher(customized)



Diameter flow comparison table

Diameter(mm)
Standard Range (m3/h)
Extended Range(m3/h)
4
0.04~0.25
0.04~0.4
6
0.1~0.6
0.06~0.6
10
0.2~1.2
0.15~1.5
15
0.6~6
0.4~8
20
0.8~8
0.45~9
25
1~10
0.5~10
32
1.5~15
0.8~15
40
2~20
1~20
50
4~40
2~40
65
7~70
4~70
80
10~100
5~100
100
20~200
10~200
125
25~250
13~250
150
30~300
15~300
200
80~800
40~800

Product

KTFM-R remote type

The site itself does not have a display function, only the flow of remote signal output, signal flow can be divided into pulse signal and current signal, Especially suitable for the secondary display instruments, PLC, DCS and other control systems with the computer.
Parameter
Value
Power supply
24VDC±15% (Ripply≤5%, Power waste<0.5W)
Input signal frequency range
0~3000Hz
4-20mA output
Load capacity
≤600Ω
Pulse output
Load capacity
>1100Ω
High/Low level amplitude
>22V / <0.8V
Pulse width
1/2fin×1000(ms)

KTFM-S smart integrated display type

The site itself with field display function, the flow signal can be remote output, two display units available, multiple electrical signal output mode optional.
Parameter
Value
Power supply
External power
24VDC±15% (Ripply≤5%, Power waste<0.5W)
Internal Power
3VDC lithium battery
(working voltage 2.0V~3.0V,Sustainable work for more than 12 months)
Input signal frequency range
0~3000Hz
Pulse output
Load capacity
>1100Ω
High/Low level amplitude
>22V / <0.8V
Pulse width
1/2fin×1000(ms)
Current output
Load capacity
≤900Ω
Two-wire
4-20mA
Three-wire
0-20mA
Communication interface
RS485, Using MODBUS

KTFM-L low power type

Backlit dot matrix LCD display, full English display, power waste low, multiple display units are available and multiple electrical signal output mode optional.
Parameter
Value
Power supply
External power
24VDC±15% (Ripply≤5%, power waste<0.5W)
Internal power
3.6VDC lithium battery
(working voltage 2.3V~3.6V,Sustainable work for more than 12 months)
Input signal frequency range
0~3000Hz
Pulse output
Load capacity
>1100Ω
High/Low level amplitude
>22V / <0.8V
Pulse width
1/2fin×1000(ms)
Current output
Load capacity
≤880Ω
Two-wire
4-20mA
Three-wire
4-20mA
Communication interface
RS485, Using MODBUS

KTFM-M Mini type

Repeatability ±0.25% has strong corrosion resistance, suitable for high temperature, high pressure and harsh environments.

Parameter
Value
Range
Diameter(mm)
Measuring range(L/min)
Meter factor (cm3/imp)
1.15
0.035~1.60
0.50
1.30
0.010~1.86
0.60
1.50
0.045~2.08
0.67
2.00
0.085~2.32
1.02
2.50
0.120~2.40
1.44
3.70
0.150~3.00
2.28
Max pressure
20.0bar
Pressure lose
2.0bar
Temp. range
-10°C/+100°C
Accuracy level
±1%
Pipe connection
G1/4 Internal thread(Customizable)
Installation mode
Horizontal installation
Dimension(L×B×H)
55×40×47mm
Weight
About 300g
Certification
NSF,CE

Dimension


Diagram 1(DN4~DN10): Threaded connection type turbine flow sensor (including straight pipe section).
Diagram 2(DN15~DN40): Thread connected flow sensor size drawing.
Diagram 3(DN15~DN20): Flange connected turbine flow sensor drawing.
Sensor installation method according to different specifications, Adopt thread or flange connection, the installation method is shown in diagram 1, 2, 3.

Installation dimensions

Diameter(mm)
L(mm)
G
K(mm)
D(mm)
n(hole)
4
225
G1/2
6
225
G1/2
10
345
G1/2
15
75
G1
Φ65
Φ14
4
20
80
G1
Φ75
Φ14
4
25
100
G5/4
Φ85
Φ14
4
32
140
G2
Φ100
Φ14
4
40
140
G2

China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Turbine Flow Meter / Diesel Flow Meter Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Xi'an Kacise Optronics Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0